Polaris Digital Wrench
Polaris Digital Wrench
On-line Help System
Glossary    Contact Us
Search  
   
Browse by Category
Polaris Digital Wrench .: Errors and Troubleshooting .: General Problems .: Run Time Error 3706, Provider Not Found

Run Time Error 3706, Provider Not Found

Version: ALL
Operating System(s): ALL

Description:

When the Digital Wrench is started, an error message comes up stating "Run Time Error 3706, Provider Not Found".

This error usually comes up the first time the software is run after it is installed or after some other type of software application has been loaded on the PC

Cause:

This particular error is caused when either the Microsoft Jet Database, or Data Access Components (MDAC) portions of Windows are damaged or missing.  When the Digital Wrench tries to open it's vehicle database the Windows Database Drivers are not there or don't work.

Solution:

Most often, using the Registry Cleanup Utility described in the How to run the DWRegCleanUp Utility" Article followed by reinstalling the Digital Wrench Software will solve the problem

Click here to view the DWRegCleanUp Article

If reinstalling does not solve the problem, Reinstall MDAC and the Jet Database Drivers described in the following two articles

Reinstalling MDAC

Reinstalling Jet


How helpful was this article to you?

Related Articles

article PROBLEMS ? READ THIS FIRST
Version: Digital Wrench 2.06 - PresentOperating System(s): AllDescription:Before you

  11-11-2004    Views: 8239   
article Runtime Error 91
Version: ALL Operating System(s): ALL...

  10-9-2004    Views: 3080   
article InstallShield Error 1607
Version: 2.06 - PresentOperating System(s): ALLDescription:When the Digital Wrench I

  10-12-2004    Views: 5337   
article Runtime Error 8002801D
Version: AllOperating System(s): Windows 98Description:When the Digital Wrench is st

  11-5-2004    Views: 23236   
article Registry Script Error when using the DWRegCleanup Utility
Version: Digital Wrench 2.08Operating System(s): Windows 95, 98, ME and NT 4.0Description:

(No rating)  11-3-2004    Views: 33822   

User Comments

Add Comment
No comments have been posted.


.: Powered by Lore 1.4.3
[ Admin Login ]
Copyright 2004 Diagnostic Systems Associates Inc.